Product Features
Advanced Liquid-Cooling System for Optimal Thermal Management
Liquid cooling provides superior heat dissipation compared to air cooling, maintaining consistent battery temperatures even during heavy operation. This enhances efficiency, extends battery life, and enables high-power performance with minimal thermal degradation.
Enhanced Safety and Longevity
Liquid-cooled systems operate at stable temperatures, reducing risks of overheating and thermal stress, which in turn enhances safety. This stability also prolongs the battery’s operational lifespan, resulting in fewer replacements and lower long term maintenance costs.
High Energy Density and Power Output
Designed for energy- intensive applications, liquid-cooled storage cabinets offer high energy density and large power output. This makes them well-suited for industries and facilities with large energy demands, peak shaving, and continuous backup power requirements.
Real-Time Monitoring and Intelligent Controls
Equipped with advanced monitoring and control systems, these cabinets track temperature, voltage, and performance metrics in real time. The intelligent controls allow for remote management, predictive maintenance, and automated safety responses, ensuring efficient and reliable operation.
Technical Specification for 2 hours Backup (0.5C)
Model | 100kW 215kWh |
100kW 232kWh |
125kW 241kWh |
125kW 252kWh |
125kW 261kWh |
DC (Battery) | LiFePO4 Lithium Iron Phosphate | ||||
Cells Type | 3.2V280Ah | 3.2V280Ah | 3.2V314Ah | 3.2V304Ah | 3.2V314Ah |
Cell specification | 240S1P | 260S1P | 240S1P | 260S1P | 260S1P |
Configuration of Battery | 215kWh | 232kWh | 241kWh | 252kWh | 261kWh |
Battery Capacity | 100KW | 100KW | 100KW | 100KW | 100KW |
Max. Power | 140A | 140A | 157A | 152A | 157A |
Max. Current | 768V | 728V-936V | 768V | 832V | 832V |
Battery Rated Voltage | 672V-864V | 728V-936V | 672V-864V | 728V-936V | 728V-936V |
Battery Voltage Range | AC (On/Off Grid) | ||||
Max. Power(kVA) | 110KVA | 110KVA | 110KVA | 137KVA | 125KVA |
Active Power(kW) | 100KW | 100KW | 100KW | 125KW | 125KW |
Rated Voltage(V) | 400V | 400V | 400V | 400V | 400V |
Rated Current(A) | 144A | 144A | 144A | 180A | 180A |
Voltage Range | 320V-460V | ||||
Rated Frequency | 50/60Hz | ||||
Range of Frequency | 45-55/55-65Hz | ||||
THDI | <3% | ||||
Power factor | 1.0 (Adjustable from 0.8 leading to 0.8 lagging) | ||||
AC System | 3 phase 4 wires | ||||
Overload capability | 110% | ||||
Solar Side (PV) | |||||
Max. Power | Optional | ||||
Max. Power | 100KW (50KW*2) | ||||
High Volage side Voltage | 560V-1000V | ||||
High Voltage side Current | 160A | ||||
Low Voltage side Voltage | 500V-900V | ||||
Low Voltage side Current | 200A | ||||
Uninterrupted Load (STS) | Optional | ||||
STS Power | 200KW | ||||
STS Voltage | 400V 50HZ/60HZ | ||||
Overload Power | 110% | ||||
Shift Time | <20ms | ||||
System operation strategy | Anti Backflow and Black Start | ||||
Functional | Power peak shaving and valley filling, electricity price peak valley arbitrage, photovoltaic priority for electricity cost savings, wind power generation priority for electricity cost savings, off grid power supply for remote areas | ||||
Operation Mode Selections | Photovoltaic and diesel storage project, Wind power and diesel storage project, Wind and photovoltaic diesel storage project, Charging Station + Energy storage project, On-grid electricity selling project | ||||
Specification | |||||
Cabinet Size (W * D * H) | 1585/1366/2055mm | ||||
Weight | ≤2.7T | ||||
Max. cycle efficiency | >90% | ||||
Protection | IP55 | ||||
Auxiliary Power Supply | Self-powered, Externally powered | ||||
Corrosion resistance rating | C3/C5 | ||||
Operating Humidity Range | 0%-100% (Non-condensing) | ||||
Operating Temperature Range | -30°C-50°C (>45°C derating) | ||||
Max. Operation Altitude | 2000m | ||||
Battery cabinet cooling method | Intelligence Liquid Cooling | ||||
Fire safety configuration | Smoke detector, Heat detector, Gas-based fire extinguishing system, Pressure relief valve, Pack-level fire protection, Cluster-level fire protection, Water-based fire protection, Automatic pressure relief | ||||
Communication | Ethernet, 485, CAN | ||||
Communication Protocol | Modbus TCP | ||||
Note: Some spare parts are available. For details, please consult with our sales for further communication. |