Features
- IP65~lP67 waterproof level.
- Integrated AC bus cable, Ready-To-Use.
- WlFl communication and cloud monitoring.
- Output voltage is automatically recognized.
- Compatible with a variety of conventional solar panels.
- Unique reverse transmission technology gives priority to the load.
- Excellent low light lock function (APL) and higher conversion ef ciency.
Specification
| Model | GYSMI-600W | GYSMI-700W | GYSMI-800W |
| Input Data (DC, PV) | |||
| Number of Input MC4 Connector | 2 sets | ||
| MPPT Voltage Range | 22V~48V | 22V~48V | 22V~48V |
| Operation Voltage Range | 18V~60V | 18V~60V | 18V~60V |
| Maximum Input Voltage | 60V | 60V | 60V |
| Startup Voltage | 22V | 22V | 22V |
| Maximum Input Power | 600W | 700W | 800W |
| Maximum input Current | 12A*2 | 14A*2 | 16A*2 |
| Output Data(AC) | |||
| Single-Phase Grid Type | 120V&230V | 120V&230V | 120V&230V |
| Rated Output Power | 600W | 700W | 800W |
| Maximum Output Power | 600W | 700W | 800W |
| Nominal Output Current | @120VAC:5A @230VAC:2.6A | @120VAC:5.8A @230VAC:3A | @120VAC:6.6A @230VAC:3.4A |
| Nominal Output Voltage | 120VAC / 230VAC | ||
| Default Output Voltage Range | @120VAC:80V~160V @230VAC:180V~270V | ||
| Nominal Output Frequency | 50Hz/60Hz | ||
| Default Output Frequency Range | @50Hz:48Hz~51Hz @60Hz:58Hz~61Hz | ||
| Power Factor | >0.99% | ||
| Total Harmonic Distortion | THD <5% | ||
| Maximum Units per Branch | @120VAC:5units @230VAC: 6units | ||
| Efficiency | |||
| Peak Efficiency | 95% | ||
| Nominal MPPT Efficiency | 99.5% | ||
| Night Power Consumption | <1W | ||
| Mechanical Data | |||
| Operating Ambient Temperature Range | -40°C to +65°C | ||
| Storage Temperature Range | -40°C to +85°C | ||
| Dimensions(W*H *D) | 310mmx185mm x 45mm (not include connectors and cable) | ||
| Weight | 2kg | ||
| Max Current of AC Bus Cable | 20A | ||
| Waterproof Grade | IP66 | ||
| Cooling Mode | Natural Convection – No Fans | ||
| Other Features | |||
| Communication | WIFI (Cloud monitoring) | ||
| Transformer Design | High Frequency Transformers, Galvanically Isolated | ||
| Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | ||
| Protection Functions | Isolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc. | ||
| Design Compliance | EN IEC6000-3-2:2019+A1:2021,EN 61000-3-2:2019+A1:2019+A2:2021, EN IEC55014-2:2021,EN IEC55014-1:2021 | ||
Product specifications are subject to change without prior notice.