GYS 100HS-215KWH Microgrid All-in-one Inverter/Controller
GYS 100-150HS Microgrid All-in-one Inverter/Controller
GYS 250H Microgrid All-in-one Inverter/Controller
GYS 3315K-15/30--45KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 3312K-15/30KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 12K-15/30KWH All-in-One Hybrid Inverter
GYS 10K-10/15KWH All-in-One Hybrid Inverter
GYS 6K-7.68/10/15KWH All-in-One Hybrid Inverter
GYS 3.2K-3.8KWH GYS 5K-5/10KWH All-in-One Hybrid Inverter
Traction and Eco-eriendly Vehicle Batteries
RV Energy Storage Lithium Battery
GYS 5KWH-L GYS 10KWH-L GYS 15KWH-L Microgrid All-in-one Inverter/Controller
GYS 5KWH-D Microgrid All-in-one Inverter/Controller
GYPV/16-1 DC Combiner Box
GYPV/12-1 DC Combiner Box
GYPV/8-1 DC Combiner Box
GYPV/6-1 DC Combiner Box
GYPV/4-1 DC Combiner Box
GYPV/2-1 DC Combiner Box
GYPV/1-1 DC Combiner
AO (7kW/11kW/22kW) AC Charging Point
TYPE 2 AO (7kW/11kW/22kW) Smart AC Wallbox
T1-1P (2.3kW/3.0kW/3.68kW) IC-CPD Portable AC Charger
T1-7.4kW 1P IC-CPD Portable AC Charger
T1-11kW 3P IC-CPD Portable AC Charger
GYM9H-DC-C16 4P
GSP9-C40 Surge Protective Device
GSP9-C40PV 1500V DC Surge Protective Device
GSP9-C40PV 600V 1000V DC Surge Protective Device
GYM7DC New Energy High Voltage Circuit Breaker
GYM9H DC Miniature Circuit Breaker
GYM9H DC Miniature Circuit Breaker
W2R Automatic Transfer Switch
GYM9H DC Miniature Circuit Breaker
GYM9H DC Miniature Circuit Breaker

GYM9H DC Miniature Circuit Breaker

GYM9H DC Circuit Breaker is designed for DC circuits with a rated voltage up to 1000V and a rated current up to 63A. It provides overload and short-circuit protection and can also be used for infrequent switching operations of circuits. This circuit breaker is suitable for DC system applications, such as communications and photovoltaic (PV) systems. Compliance Standards: IEC/EN 60947-2, GB/T 14048.2.

◉ Reliable Protection: Provides effective overload and short-circuit protection for DC systems up to 1000V/63A.
◉ Standard Compliance: Complies with IEC/EN 60947-2 and GB/T 14048.2 standards; RoHS 2.0 compliant.
◉ Convenient Wiring & Status: Dual busbar wiring function, transparent marking feature, and contact position indicator.
◉ Compact & Durable: Supports maximum wire capacity of $16\text{ mm}^2$ with high mechanical and electrical endurance.

Features

Overview

GYM9 DC Circuit Breaker is designed for DC circuits with a rated voltage up to 1000V and a rated current up to 63A. It provides overload and short-circuit protection and can also be used for infrequent switching operations of circuits.
This circuit breaker is suitable for DC system applications, such as communications and photovoltaic (PV) systems.
Compliance Standards: IEC/EN 60947-2 GB/T 14048.2

  • RoHS 2.0 compliant
  • Dual busbar wiring function
  • Transparent marking feature
  • Contact position indicator
  • Max. wire capacity: 16mm²

 

Technical Specification

  • Rated Current(In): 1-63A
  • Rated Voltage(Ue): 1P:250VDC;2P:500VDC;3P:750VDC;4P:1000VDC
  • Tripping Curves: B、C、D
  • Rated insulation voltage(Ui): 500V
  • Breaking Capacity: 6kA
  • Poles: 1P、2P、3P、4P
  • Mechanical life: 20000 times
  • Electrical life: 10000 times
  • Tightening moment: 2.0N.m
  • Class of protection: Ip20

Wiring Diagram
GYM9H DC Miniature Circuit Breaker-1

Outline Overall And Installing Dimensions

GYM9H DC Miniature Circuit Breaker-2

Temperature Compensation

When the ambient temperature is not the baseline temperature of 30℃, the reference Correction coefficientis as follows:

Ambient Temperature -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C
Current Correction Factor 1.25 1.2 1.15 1.10 1.05 1.00 0.95 0.90 0.85