GYS 100HS-215KWH Microgrid All-in-one Inverter/Controller
GYS 100-150HS Microgrid All-in-one Inverter/Controller
GYS 250H Microgrid All-in-one Inverter/Controller
GYS 3315K-15/30--45KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 3312K-15/30KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 12K-15/30KWH All-in-One Hybrid Inverter
GYS 10K-10/15KWH All-in-One Hybrid Inverter
GYS 6K-7.68/10/15KWH All-in-One Hybrid Inverter
GYS 3.2K-3.8KWH GYS 5K-5/10KWH All-in-One Hybrid Inverter
Traction and Eco-eriendly Vehicle Batteries
RV Energy Storage Lithium Battery
GYS 5KWH-L GYS 10KWH-L GYS 15KWH-L Microgrid All-in-one Inverter/Controller
GYS 5KWH-D Microgrid All-in-one Inverter/Controller
GYPV/16-1 DC Combiner Box
GYPV/12-1 DC Combiner Box
GYPV/8-1 DC Combiner Box
GYPV/6-1 DC Combiner Box
GYPV/4-1 DC Combiner Box
GYPV/2-1 DC Combiner Box
GYPV/1-1 DC Combiner
AO (7kW/11kW/22kW) AC Charging Point
TYPE 2 AO (7kW/11kW/22kW) Smart AC Wallbox
T1-1P (2.3kW/3.0kW/3.68kW) IC-CPD Portable AC Charger
T1-7.4kW 1P IC-CPD Portable AC Charger
T1-11kW 3P IC-CPD Portable AC Charger
GYM9H-DC-C16 4P
GSP9-C40 Surge Protective Device
GSP9-C40PV 1500V DC Surge Protective Device
GSP9-C40PV 600V 1000V DC Surge Protective Device
GYM7DC New Energy High Voltage Circuit Breaker
GYM9H DC Miniature Circuit Breaker
GYM9H DC Miniature Circuit Breaker
W2R Automatic Transfer Switch
GY-ASVG-Cabinet
GY-ASVG-Cabinet

GY-ASVG Advanced Static Var Generator – Cabinet

Product Features

GY-ASVG-Cabinet-1

 

Overview

Enhanced Static Var Generator (GY-ASVG) is mainly composed of an AC distribution unit, ASVG modules, a monitoring system, etc. The GYASVG connects a voltage source converter (VSC) to the power grid via a filter in parallel. Its working principle is to detect the load current in real time and, based on advanced detection and control algorithms for reactive power, harmonics, and three-phase active power, generate corresponding IGBT drive signals to achieve comprehensive compensation of reactive current, harmonic current, and three-phase unbalanced current. The device adopts a modular design, offering high integration density as well as convenient and flexible installation.

 

Performance characteristics

(1) DSP+CPLD full-digital control core, three-level topology technology.
(2) Modular design with multi-module parallel connection; small footprint, easy maintenance.
(3) Independent air duct and independent board compartment design to ensure stable operation of the equipment.
(4) Equipped with two external current sampling channels, supporting various compensation modes such as low-voltage side sampling with low-voltage side compensation, highvoltage side sampling with low-voltage side compensation, and reactive component compensation.
(5) Supports any one, any two, or all three of reactive power compensation, harmonic compensation, and three-phase unbalance compensation as selectable options.
(6) Reactive power compensation capability: compensation rate ≥99%.
(7) Unbalance compensation capability: unbalance degree after compensation ≤5%.
(8) Current harmonic compensation capability: compensation rate ≥95%; 2nd to 50th harmonics, individual compensation rate adjustable.
(9) Neutral line zero-sequence current filtering capacity is twice that of the phase line (triple customizable).

Technical Parameter

Model 220V 380V 500V 690V 800V
Altitude <2000m; above 2000 m, derate according to GB/T 3859.2
Ambient temperature -10 ~ +50℃ (above 40 ℃, capacity derating ≤30%)
Relative humidity ≤90% relative humidity, no condensation on the surface at a monthly minimum temperature of 25 ℃
Pollution degree Pollution degree ≤ Class III
Operating voltage AC220V (-20%~+20%) AC380V (-20%~+20%) AC500V (-20%~+20%) AC690V (-20%~+15%) AC800V (-20%~+850V Max)
Operating frequency 50Hz/60Hz (45Hz~63Hz)
Rated compensation capacity 50kvar ~ 300kvar 100kvar ~ 600kvar 90kvar ~ 540kvar 100kvar ~ 720kvar 150kvar ~ 900kvar
Grid configuration Three‑phase three‑wire, Three‑phase four‑wire Three‑phase three‑wire
Number of parallel units No restrictions
Overall efficiency ≥97%
Switching frequency 16kHz 12.8kHz
Function selection A、B、A+B、B+A、B+C、A+C、B+C+A、A+C+B A、B、A+B
Reactive compensation rate Reactive power compensation ≥95% NO
Unbalance compensation capability Unbalance degree after compensation ≤5%
Current harmonic compensation capability Harmonic comp.(current) ≥95%
Neutral line filtering capability Neutral line filtering capacity is twice that of phase filtering capacity (triple customizable)
Full response time Reactive power <10ms, Harmonics <40ms
Noise level ≤75dB
Communication method 2 RS485 communication interfaces (Wi‑Fi supported)
Protection functions Overload, software/hardware overcurrent, grid over‑undervoltage, grid voltage unbalance, power supply failure, overtemperature, frequency anomaly, short‑circuit protection, etc.
Overload capability Rated overload 1.2 times for 60 seconds
Installation method Rack‑mount / Wall‑mount
Cable entry Rack‑mount: rear cable entry; Wall‑mount: top cable entry
Protection rating IP20 (IP54 available on request / customizable)