Features
- Supports flexible expansion of PV capacity
- Integrated EMS function – safe and stable
- Supports simultaneous connection of load, battery, grid, diesel generator, and PV
- Supports battery capacity and discharge time prediction
- Built-in isolation transformer – strong load adaptability
- Application scenarios: solar-storage microgrids, backup power, emergency power, diesel-storage systems, construction sites, oilfield extraction, remote field operations, etc.
Technical Parameter
| Product Specifications | GYS 100HS-215KWH |
| AC parameters | |
| Rated power (kW) | 100 |
| Rated voltage (V) | 400 |
| Rated current (A) | 144 |
| Voltage range (V) | 320-460 |
| Rated frequency (Hz) | 50/60 |
| Frequency range (Hz) | 45-55/55-65 |
| THDI (grid-tied) | <3% |
| THDu (off-grid) | ≤1% linear; ≤5% nonlinear |
| Power factor | 1 Lead ~ 1 Lag (Configurable) |
| Overload capability | 110%长期 |
| Grid type | 3W+N+PE |
| Isolation transformer | Have |
| Grid-tied / off-grid transfer | Support |
| PV parameters | |
| Max PV input voltage (V) | 1,000 |
| Max PV power (kW) | 165/247.5 |
| MPPT operating voltage range (V) | 250~1,000 |
| Buck-boost mode | Adaptive |
| Battery parameters | |
| Battery type | 3.2V/280Ah/LFP |
| Rated voltage (V) | 768V, 1P240S |
| Rated energy (kWh) | 215.04 |
| Operating voltage range (V) | 672~852 |
| Max charge/discharge rate | 0.5P@25℃ |
| General parameters | |
| Dimensions W×D×H (mm) | 2,460×1,560×2,425 |
| Weight (kg) | 3,900 |
| Operating temp. range (℃) | 0~+45 |
| Relative humidity (no cond) | 0-85% (No condensation) |
| Protection rating | IP54 |
| Noise (dB) | <75 |
| Max operating altitude (m) | 2,000(>2,000 Power derating) |
| Cooling method | Temperature-controlled smart air cooling |
| Fire suppression system | Aerogel/Perfluorohexanone (optional) |
| Display | Touchscreen LCD Display Cloud Platform |
| EMS communication | RS485, TCP/IP |