GYS 100HS-215KWH Microgrid All-in-one Inverter Controller energy storage system cabinet
GYS 100-150HS Microgrid All-in-one Inverter Controller energy storage system
GYS 250H Microgrid All-in-one Inverter Controller for Industrial Energy Systems
GYS 3315K Three-phase All-in-one PV Storage Inverter
GY-S 3312K-15/30KWH three-phase all-in-one PV storage inverter controller
GYS 12K-15/30KWH All-in-One Hybrid Inverter front view
GYS 10K-10/15KWH All-in-One Hybrid Inverter front view
GYS 6K all-in-one hybrid inverter front view with integrated battery storage system
GYS 3.2K-5K All-in-One Hybrid Inverter front view with LiFePO4 battery storage system
GY-AVC-PLUS Unified Power Quality Control Device for voltage regulation and power quality improvement
GY-ASVG Advanced Static Var Generator Cabinet for reactive power compensation and power quality management
GY-ASVG-IU Rack-mount Static Var Generator side view showing slim 1U cabinet structure
GY-ASVG-LN Low-noise Static Var Generator side view with compact modular structure
GY-ASVG-SiC Advanced Static Var Generator SiC power semiconductor technology details
GY-ASVG-PLUS Static Var Generator cabinet design for industrial power systems
GY-AHF Active Harmonic Filter Cabinet for industrial power quality management
GY-AHF-SiC-based Active Harmonic Filter using silicon carbide technology for industrial power quality improvement
GY-AHF-PLUS Active Harmonic Filter cabinet side view with modular power quality design
GY-SVG Static Var Generator Cabinet for industrial reactive power compensation and power quality improvement
GY-SVG-SiC Static Var Generator front view for reactive power compensation
GY-SVG-PLUS High-Spec Static Var Generator front view for reactive power compensation
Traction and eco-friendly vehicle LiFePO4 battery pack for electric vehicles and industrial applications
RV energy storage lithium battery with LiFePO4 cells for caravan and camper power systems
GYS 5KWH-L 10KWH-L 15KWH-L low voltage LiFePO4 battery energy storage system exterior view
GYS 5KWH-D low voltage LiFePO4 battery energy storage system exterior view
GYPV/16-1 DC Combiner Box for 16 String Solar PV Systems
GYPV/12-1 PV Combiner Box with 12 string inputs for solar photovoltaic systems
GYPV/8-1 DC Combiner Box with 8 string inputs for solar photovoltaic systems
GYPV/6-1 DC PV Combiner Box Outdoor Solar Protection Box
GYPV/4-1 DC PV Combiner Box Side View with IP65 Protection
GYPV/2-1 DC PV Combiner Box Front View for Small Solar Systems
GYPV/1-1 DC Combiner Box side view with IP65 protection enclosure
AO 7kW 11kW 22kW AC Charging Point for Electric Vehicles
TYPE 2 AO 7kW 11kW 22kW Smart AC Wallbox EV Charger
T1-1P 2.3kW 3.0kW 3.68kW IC-CPD Portable AC EV Charger
T1 Series 7.4kW IC-CPD Portable AC EV Charger
T1 11kW 3 Phase IC-CPD Portable AC EV Charger for Electric Vehicles
GEYA GYM9H-63-ZW 1P 10kA DC Miniature Circuit Breaker for PV Solar System
GEYA GYM9H-63-ZW 1P 10kA DC Miniature Circuit Breaker for PV Solar System
GEYA GYM10-DC 1P 6-63A DC Miniature Circuit Breaker for PV Solar System
GYPV-1038 solar fuse holder modular protection component
GYH8-63 DC Switch Disconnector product image
geya-gyl9-b-type-b-rcd-4
GYM9H-DC C16 2P DC Miniature Circuit Breaker for Photovoltaic Systems
GSP9-C40 2P 40kA Surge Protection Device for Electrical Systems
GSP9-C40PV 1500V DC Surge Protective Device for Solar PV System Protection
GSP9-C40PV 600V 1000V DC Surge Protective Device for Solar PV System Protection
GYM7DC New Energy High Voltage DC Circuit Breaker for Solar PV and Energy Storage Systems
GYM9H-125 2P DC Miniature Circuit Breaker for Photovoltaic Systems
Skip image slider
GY-SVG-PLUS High-Spec Static Var Generator front view for reactive power compensation
GY-SVG-PLUS High-Spec Static Var Generator front view for reactive power compensation
GY-SVG-PLUS Static Var Generator cabinet angle view for industrial power systems
GY-SVG-PLUS Static Var Generator side structure and installation design
GY-SVG-PLUS Static Var Generator control interface and equipment details
GY-SVG-PLUS modular Static Var Generator design for flexible power expansion
GY-SVG-PLUS Static Var Generator power quality management solution equipment

GY-SVG-PLUS High-spec Static Var Generator

GY-SVG-PLUS is a high-performance Static Var Generator designed for advanced reactive power compensation and power quality improvement. It adopts DSP+CPLD full-digital three-level control technology to achieve real-time reactive power compensation, three-phase unbalance correction and zero-sequence current compensation. With fast dynamic response, high compensation accuracy and flexible installation options, it provides reliable power quality solutions for industrial and commercial electrical systems.

•Fast Dynamic Compensation — Transient response <50μs · full response <10ms for rapid reactive power adjustment and stable power quality control.
•High-Precision Reactive Compensation — Compensation accuracy ≥99% · power factor improved to ≥0.99 with bidirectional reactive power regulation.
•Three-Phase Unbalance Correction — Real-time unbalance compensation with residual unbalance ≤5% for improved system stability.
•Neutral Current Compensation — Zero-sequence current compensation up to 3× phase line current for enhanced three-phase four-wire system performance.
•Flexible CT Sampling & Expansion — Dual external CT channels support LV-side, HV-side and load-side sampling · modular design enables parallel capacity expansion.
•Industrial EMC Reliability — Class A EMC (RE & CE) compliance · optimized cooling structure and isolated PCB design for reliable operation.

Product Features

GY-SVG-PLUS Static Var Generator working principle for dynamic reactive power compensation

 

Overview

Working principle of the high-configuration model Static Var Generator (GY-SVG-PLUS):
The device connects a voltage source converter (VSC) to the power grid via a filter in parallel. By adjusting the amplitude and phase of the output voltage on the AC side of the converter, it dynamically and accurately compensates for reactive power in the grid system. The transient response time is less than 50 μs, and the full response time is less than 10 ms, thereby avoiding over-compensation and under-compensation. In addition, the device’s neutral line zero-sequence current filtering capability can reach three times the phase line current. It also offers improved EMC electromagnetic compatibility performance and better stability.

 

Performance characteristics

1.DSP+CPLD full digital control core, three-level topology technology, advanced reactive power detection algorithm, and PWM control strategy.
2.Modular design, supports paralleling of multiple modules, small footprint, easy maintenance.
3.Independent air duct and independent board compartment structure design to ensure stable operation of the device.
4.Equipped with two external current sampling channels, supporting various compensation modes such as low-voltage side sampling with low-voltage side compensation, high-voltage side sampling with low-voltage side compensation, and reactive component compensation.
5.Supports selectable compensation modes: reactive power compensation, or reactive power compensation + three-phase unbalance compensation.
6.Reactive power compensation capability: compensation rate ≥ 99%.
7.Unbalance compensation capability: unbalance degree after compensation ≤ 5%.
8.Neutral line zero-sequence current filtering capability is three times that of the phase line current.
9.Dynamic response speed to load is millisecond level, enabling dynamic and accurate compensation for impact reactive power loads.
10.EMC electromagnetic compatibility: RE and CE items meet Class A test standard.

Technical Parameter

Model 220V 380V
Altitude <2000m; above 2000 m, derate according to GB/T 3859.2
Ambient temperature -10 ~ +50℃ (above 40 ℃, capacity derating ≤30%)
Relative humidity ≤90% relative humidity, no condensation on the surface at a monthly minimum temperature of 25 ℃
Pollution degree Pollution degree ≤ Class III
Operating voltage AC220V (-20%~+20%) 380V (-20%~+20%)
Operating frequency 50Hz/60Hz (45Hz~63Hz)
Rated compensation capacity 37kvar、50kvar 75kvar、100kvar
Grid configuration Three‑phase three‑wire, three‑phase four‑wire
Number of parallel units unlimited
Overall efficiency ≥97%
Switching frequency 16kHz
Function selection Reactive power compensation / Reactive power compensation + three‑phase unbalance compensation
Reactive compensation rate Reactive power compensation ≥99%
Unbalance compensation capability Unbalance degree after compensation ≤5%
Full response time <10ms
Noise level ≤65dB
Communication method 2 RS485 communication ports (Wi‑Fi supported)
Protection functions Overload, software/hardware overcurrent, grid overvoltage/undervoltage, grid voltage unbalance, power supply failure, overtemperature, frequency anomaly, short‑circuit protection, resonance protection, etc.
Overload capability Rated 1.2 times overload for 60 seconds
Installation method Rack / Wall‑mounted
Cable entry Rear cable entry (rack‑mount), top cable entry (wall‑mounted)
Protection rating IP20 (IP54 customizable)
Neutral line filtering capability Neutral line filtering capacity is 3 times that of phase filtering capacity
Cooling method Forced air cooling
Electromagnetic compatibility EMC (Electromagnetic Compatibility)‑ Radiated Emission (RE) and Conducted Emission (CE) meet Class A test standard

User Manual

Frequently Asked Questions About GY-SVG-PLUS High-Spec Static Var Generator

What is the GY-SVG-PLUS?
GY-SVG-PLUS is a high-spec Static Var Generator designed for dynamic reactive power compensation and power quality improvement. It uses DSP+CPLD three-level digital control technology to monitor grid conditions in real time and generate accurate compensation currents according to system requirements. The product supports reactive power regulation, three-phase unbalance correction and zero-sequence current compensation, providing stable and efficient power quality management for industrial and commercial electrical systems.
What functions does the GY-SVG-PLUS provide?
GY-SVG-PLUS provides comprehensive compensation functions including bidirectional reactive power compensation with accuracy up to ≥99%, power factor improvement to ≥0.99, and three-phase unbalance correction with residual unbalance ≤5%. It also supports neutral-line zero-sequence current compensation up to 3× phase line current, voltage fluctuation improvement and rapid response for dynamic or impact loads with full compensation response below 10ms. Multiple protection functions ensure safe and reliable operation.
What factors should be considered when selecting a GY-SVG-PLUS model?
The main selection factors include grid voltage, system configuration, required reactive power capacity and compensation objectives. Users should consider whether the system is 3P3W or 3P4W, the required kvar compensation level, reactive-only or combined unbalance compensation requirements, CT installation method, environmental conditions, protection rating and installation type. GY-SVG-PLUS supports flexible capacity expansion through parallel operation of multiple modules.
What configurations are available for GY-SVG-PLUS?
GY-SVG-PLUS is available in wall-mounted and rack-mounted configurations to meet different installation requirements. It supports 3P3W and 3P4W electrical systems, reactive power compensation or reactive power plus three-phase unbalance correction modes, and standard IP20 protection with optional IP54 customization. Multiple units can be connected in parallel for higher compensation capacity, with RS485 communication available for system monitoring.
What standards does GY-SVG-PLUS comply with and where is it used?
GY-SVG-PLUS is designed according to industrial power quality and EMC requirements. Its Radiated Emission (RE) and Conducted Emission (CE) performance comply with Class A EMC standards, and altitude derating follows GB/T 3859.2 requirements. The product is suitable for industrial plants, commercial buildings, renewable energy systems, data centers, EV charging facilities, mining, oil and gas applications and other power systems requiring reliable reactive power management.
What should be considered during installation and maintenance?
During installation, the SVG should be connected in parallel with the load, and the correct grid voltage and 3P3W or 3P4W configuration must be confirmed before operation. CT polarity and wiring accuracy should be checked before commissioning. Ensure sufficient ventilation space for forced-air cooling, maintain proper grounding and follow environmental requirements for temperature, humidity and altitude. The modular design allows convenient inspection, maintenance and replacement of internal modules when required.

Related Products

Related News

For modern industrial facilities, electrical efficiency is no longer just about how much power a facility consumes. It is also […]

Modern industrial facilities depend on electrical systems that are not only available, but also stable, efficient, and predictable. Manufacturing lines, […]

Modern industrial facilities rely heavily on stable and reliable electrical power. From automated manufacturing lines and robotic systems to data […]

Engineer Reveals: GEYA’s Top 10 Power Quality Solutions Trends for 2026   By GEYA Senior Power System Engineering ConsultantAfter more […]

Electricity is the foundation of modern industrial operations. From manufacturing plants and data centers to commercial buildings and renewable energy […]

Power Quality Management: Complete Guide to Improving Electrical Power Quality In today’s rapidly evolving energy landscape, Power Quality Management has […]

Various types of battery-based energy systems are available today. These use different storage chemistries and offer varying benefits. For a […]

Scroll to Top

Get A Free Quote Now !

Contact Form
Tell Us Your Requirements Get a professional energy storage solution tailored to your application.
aboutus