GYS 100HS-215KWH Microgrid All-in-one Inverter/Controller
GYS 100-150HS Microgrid All-in-one Inverter/Controller
GYS 250H Microgrid All-in-one Inverter/Controller
GYS 3315K-15/30--45KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 3312K-15/30KWH Three-phase All-in-one PV-storage Inverter/Controller
GYS 12K-15/30KWH All-in-One Hybrid Inverter
GYS 10K-10/15KWH All-in-One Hybrid Inverter
GYS 6K-7.68/10/15KWH All-in-One Hybrid Inverter
GYS 3.2K-3.8KWH GYS 5K-5/10KWH All-in-One Hybrid Inverter
Traction and Eco-eriendly Vehicle Batteries
RV Energy Storage Lithium Battery
GYS 5KWH-L GYS 10KWH-L GYS 15KWH-L Microgrid All-in-one Inverter/Controller
GYS 5KWH-D Microgrid All-in-one Inverter/Controller
GYPV/16-1 DC Combiner Box
GYPV/12-1 DC Combiner Box
GYPV/8-1 DC Combiner Box
GYPV/6-1 DC Combiner Box
GYPV/4-1 DC Combiner Box
GYPV/2-1 DC Combiner Box
GYPV/1-1 DC Combiner
AO (7kW/11kW/22kW) AC Charging Point
TYPE 2 AO (7kW/11kW/22kW) Smart AC Wallbox
T1-1P (2.3kW/3.0kW/3.68kW) IC-CPD Portable AC Charger
T1-7.4kW 1P IC-CPD Portable AC Charger
T1-11kW 3P IC-CPD Portable AC Charger
GYM9H-DC-C16 4P
GSP9-C40 Surge Protective Device
GSP9-C40PV 1500V DC Surge Protective Device
GSP9-C40PV 600V 1000V DC Surge Protective Device
GYM7DC New Energy High Voltage Circuit Breaker
GYM9H DC Miniature Circuit Breaker
GYM9H DC Miniature Circuit Breaker
W2R Automatic Transfer Switch
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-02
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-03
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-04
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-05
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-02
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-03
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-04
GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-05

GY-AHF-PLUS High-spec Active Harmonic Filter

Product Features

GY-AHF-PLUS-High-spec-Active-Harmonic-Filter-1

 

Overview

Working Principle of the High-configuration Model Active Power Filter (GY-AHF-PLUS):
The device connects a voltage source converter (VSC) to the power grid via a filter in parallel. By detecting the load current in real time, it separates the harmonic currents sequentially based on a specific-order harmonic current detection algorithm. According to the set filtering percentage, it generates control signals to drive the IGBT to output a compensation current that has the same amplitude as but opposite phase to the load harmonic current, thereby achieving harmonic compensation. In addition, the device’s neutral line zero-sequence current filtering capability can reach three times the phase line current. It also offers better EMC electromagnetic compatibility performance and improved stability.

 

Performance characteristics

1.DSP+CPLD full-digital control core, three-level topology technology, advanced harmonic detection algorithm and PWM control strategy.
2.Modular design with multi-module parallel connection capability; small footprint and easy maintenance.
3.Independent air duct and independent board compartment structural design to ensure stable operation of the equipment.
4.Supports 100% current-limiting output to ensure long-term stable operation of the equipment.
5.Supports selectable compensation modes: harmonic compensation only, or harmonic compensation + three-phase unbalance compensation.
6.Unbalance compensation capability: unbalance degree after compensation ≤5%.
7.Current harmonic compensation capability: compensation rate ≥95%; 2nd to 50th harmonics, individual compensation rate adjustable.
8.Neutral line zero-sequence current filtering capacity is three times that of the phase line.
9.EMC (Electromagnetic Compatibility) – Radiated Emission (RE) and Conducted Emission (CE) meet Class A test standard.

Technical Parameter

Model 220V 380V
Altitude <2000m; above 2000 m, derate according to GB/T 3859.2
Ambient temperature -10 ~ +50℃ (above 40 ℃, capacity derating ≤30%)
Relative humidity ≤90% relative humidity, no condensation on the surface at a monthly minimum temperature of 25 ℃
Pollution degree Pollution degree ≤ Class III
Operating voltage AC220V (-20%~+20%) 380V (-20%~+20%)
Operating frequency 50Hz/60Hz (45Hz~63Hz)
Rated compensation capacity 100A, 150A
Grid configuration Three‑phase three‑wire, three‑phase four‑wire
Number of parallel units unlimited
Overall efficiency ≥97%
Switching frequency 16kHz
Function selection Harmonic compensation, harmonic compensation + three‑phase unbalance compensation
Current harmonic compensation capability Current harmonic compensation ≥95%
Current harmonic compensation range 2nd to 50th harmonics, adjustable individual compensation rate
Unbalance compensation capability Unbalance degree after compensation ≤5%
Full response time <40ms
Noise level ≤65dB
Communication method 2 RS485 communication ports (Wi‑Fi supported)
Protection functions Overload, software/hardware overcurrent, grid overvoltage/undervoltage, grid voltage unbalance, power supply failure, overtemperature, frequency anomaly, short‑circuit protection, resonance protection, etc.
Overload capability Rated 1.2 times overload for 60 seconds
Installation method Rack / Wall‑mounted
Cable entry Rear cable entry (rack‑mount), top cable entry (wall‑mounted)
Protection rating IP20 (IP54 customizable)
Neutral line filtering capability Neutral line filtering capacity is 3 times that of phase filtering capacity
Cooling method Forced air cooling
Electromagnetic compatibility EMC (Electromagnetic Compatibility)‑ Radiated Emission (RE) and Conducted Emission (CE) meet Class A test standard